How To Restart A Furnace: Safe Step-by-Step Reset And Troubleshooting Guide

How To Restart A Furnace: Safe Step-by-Step Reset And Troubleshooting Guide

How to Reset a Rheem Furnace (With Step-by-Step Instructions)

To safely restart a gas or electric furnace, turn the thermostat to "Off," locate and reset the dedicated circuit breaker, wait at least five minutes for any residual gas to safely dissipate, and flip the furnace power switch back on before setting the thermostat to "Heat" at a temperature above the ambient room reading. For older models utilizing a standing pilot light, you must manually depress the gas control valve knob while applying a flame directly to the pilot burner nozzle to establish the millivolt safety signal.

Failing furnaces can quickly turn a comfortable home into an icy, hazardous environment. Whether your heating system suffered a safety lockout, experienced a brief power surge, or had its standing pilot light blown out by a draft, knowing the correct sequence to safely restart your furnace is a vital homeowner skill. While modern heating systems possess complex safety loops governed by integrated furnace control boards, many startup failures can be resolved without calling a professional technician.

Understanding the mechanics of ignition, safety interlocks, and the physical sequence of operations allows you to execute a safe restart while identifying when a system requires professional diagnostic repair.


--- Advertisement / Sponsored Links ---
Verified by SecureScan: No Viruses Detected
Format: Adobe PDF Downloads: 12,409 Size: 2.4 MB

Pre-Restart Safety Inspections and Equipment Requirements

Before attempting to restart any furnace, you must establish a safe working environment. Gas-fired appliances operate under high pressure and utilize combustible fuel; executing a restart under unsafe conditions can lead to fuel gas accumulation, fire, or carbon monoxide exposure. Ensure you smell no rotten-egg odors (methyl mercaptan, the additive in natural gas and propane) before beginning. If you suspect a gas leak, evacuate the premises immediately and contact your utility provider.



Essential Tools, Safety Materials, and Operational Benchmarks



  • Safety Gear: Safety glasses and leather work gloves.
  • Diagnostics & Tools: A digital multimeter (for electrical testing), a flashlight, a flathead screwdriver, and a Phillips-head screwdriver.
  • Cleaning Supplies: Fine steel wool or a non-metallic abrasive pad (for flame sensor maintenance).
  • Ignition Source: A long-reach butane utility lighter (required only for older standing pilot models).
  • Prerequisite Knowledge: Location of the main home electrical panel, gas shut-off valve, and the furnace SSU switch (the toggle switch mounted on or near the furnace chassis that resembles a standard light switch).
  • Estimated Budget: $0 (Standard reset) to $35 (If basic consumables like a thermocouple or air filter require replacement).
  • Estimated Duration: 15 to 30 minutes.

Sequential Procedure for Restarting Modern and Vintage Furnaces

Follow these structured steps to perform a controlled restart of your heating system. This procedure covers both modern electronic ignition systems and legacy standing pilot models.



Step 1: De-energize the Heating System

You must first clear any active calls for heat and cut power to the control board to reset any software lockouts. Go to your thermostat and switch the system mode to "Off." Next, lower the target temperature setting below the current room temperature.

Locate your home’s main electrical service panel. Find the circuit breaker labeled "Furnace" or "Heating." Flip the breaker fully to the "Off" position, wait ten seconds, and then flip it back to the "On" position. This action resets the integrated ignition control module's microprocessor, clearing temporary soft-lockout codes.



Step 2: Clear Residual Fuel Gas and Locate the SSU Switch

Locate the furnace service switch (SSU switch) mounted on the side of the furnace cabinet or on an adjacent wall. Flip this toggle switch to the "Off" position.

If you are working on a gas furnace, wait at least five to ten minutes. This waiting period is critical: it allows any unburned gas that may have accumulated in the heat exchanger or burner manifold during failed ignition attempts to safely dissipate into the venting system or ambient air. Do not skip this step, as initiating an ignition sequence with trapped gas can cause a dangerous delayed ignition or mini-explosion within the combustion chamber.



Step 3: Remove the Access Panels and Inspect the Burner Chamber

Remove the upper burner access panel by lifting it upward and outward, or by removing the retaining screws holding it in place. Set the panel aside in a safe area.

Inspect the combustion chamber using your flashlight. Look for obvious signs of damage, such as heavy soot accumulation, rusted burner ports, or loose wiring harnesses. Verify that the gas supply line manual shut-off valve (located on the black iron pipe entering the furnace) is in the "Open" position, meaning the handle runs parallel to the gas pipe rather than perpendicular to it.



Step 4: Determine Ignition Type and Execute Restart

Furnaces utilize either a modern electronic ignition system or an older standing pilot light. The restart procedure diverges based on which system your furnace uses.

Method A: Modern Electronic Ignition (Hot Surface Igniter or Spark Ignition)

Modern furnaces do not have a constantly burning flame. They use a hot surface igniter (HSI)—a small ceramic element that glows white-hot when energized—or an intermittent spark igniter.



  1. Ensure the gas valve knob located inside the furnace cabinet is turned to the "On" position.
  2. Reinstall the upper access door securely. Many modern furnaces feature a safety door switch; if this button is not fully depressed by the door panel, the unit will not receive 120-volt power.
  3. Flip the SSU toggle switch back to the "On" position.
  4. Return to your thermostat, switch the setting to "Heat," and set the target temperature at least five degrees above the current room temperature.

Method B: Vintage Standing Pilot Ignition

Older furnaces rely on a small, continuously burning pilot flame to ignite the main burners. If this flame goes out, the thermocouple cools down, stopping the millivolt current and causing the safety valve to shut off the main gas supply.



  1. Locate the gas control valve assembly inside the burner compartment. It features a control dial with three positions: "On," "Off," and "Pilot."
  2. Rotate the dial to the "Off" position and wait five minutes for any lingering gas to clear.
  3. Rotate the dial to the "Pilot" position.
  4. Prepare your long-reach butane lighter and ignite it near the tip of the pilot burner nozzle.
  5. Fully depress the gas valve dial. This manually overrides the safety thermocouple and sends gas directly to the pilot burner.
  6. Apply the flame to the pilot burner nozzle until the gas ignites.
  7. Continue holding the gas valve dial down firmly for 45 to 60 seconds. This gives the thermocouple enough time to heat up and generate the small electrical current (around 30 millivolts) required to hold the internal safety valve open.
  8. Slowly release the dial. The pilot flame should remain lit. If it goes out, wait five minutes and repeat the process, holding the dial down longer.
  9. Once the pilot flame remains stable, turn the dial to the "On" position to enable the main gas burners. Reinstall the furnace access panel.


Step 5: Verify the System Sequence of Operation

Observe your furnace through its sight glass or open burner panel to ensure it completes its startup sequence correctly. A healthy heating cycle must follow this exact order:



  1. Draft Inducer Cycle: The draft inducer blower motor starts, exhausting any remaining combustion gases from the heat exchanger and creating a negative pressure draft.
  2. Pressure Switch Verification: The system verifies that the pressure switch contacts have closed, proving that proper combustion airflow exists.
  3. Igniter Activation: The hot surface igniter begins to glow bright orange/white, or the spark igniter begins to click.
  4. Gas Valve Engagement: The main gas valve clicks open, releasing fuel across the burner manifold.
  5. Flame Rectification: The burners ignite smoothly. Within a few seconds, the flame sensor detects the physical flame and sends a microamp signal back to the control board to keep the gas valve open.
  6. Main Blower Startup: After a brief delay of 30 to 45 seconds to let the heat exchanger warm up, the indoor blower fan activates, circulating warm air through your home's ductwork.

Ignite Your Furnace With This Simple Restart - Tiponthetrail.com

Ignite Your Furnace With This Simple Restart - Tiponthetrail.com

Furnace Ignition Systems and Technical Specifications Comparison

Understanding the technical characteristics of different ignition systems helps you troubleshoot issues during a restart. This table details the performance parameters and common failure modes of various furnace configurations.



Ignition System Type Operating Voltage Safety Mechanism Common Failure Modes Average Lifespan Fuel Efficiency Impact
Standing Pilot 30 mV (Millivolts generated by thermocouple) Thermocouple or thermopile safety loop Soot buildup on thermocouple, draft blowouts, weak pilot flame 15–30 Years Lowers efficiency (wastes gas continuously)
Intermittent Pilot 24 V (Spark generator) or 120 V (Control feed) Flame rectification rod (sensor) Cracked ceramic insulator, carbon deposits on spark electrode 10–15 Years High efficiency (gas flows only on demand)
Hot Surface Ignition (HSI) 120 V AC (Standard) or 24 V AC Flame sensor rod (microamp circuit) Cracked silicon carbide element, dirty flame sensor rod 3–5 Years (Igniter is a wear item) High efficiency (no standing pilot flame)
Direct Spark Ignition (DSI) 120 V primary / High-voltage spark arc Flame sensor rod (microamp circuit) Gap alignment issues, electrode oxidation, circuit board failure 10–15 Years High efficiency (commonly used in packaged units)

Common Furnace Startup Failures and Technical Remedies

When a furnace fails to restart, it is usually because one of its safety switches has interrupted the control circuit. Below are four common failure scenarios you might encounter during a restart, along with their root causes and solutions.



Scenario 1: The Draft Inducer Runs Continuously but Burners Never Light



  • Root Cause: The pressure switch is not closing. This safety switch prevents the furnace from firing if there is insufficient combustion airflow, a blocked chimney venting system, or a cracked heat exchanger. It can also be caused by a cracked, clogged, or water-logged vinyl sampling tube running from the inducer housing to the switch.
  • Actionable Fix: Turn off all power to the furnace. Inspect the small, flexible vinyl pressure tubing for cracks, dry rot, or condensation. Remove the tube, blow through it to clear any moisture or debris, and reinstall it securely. Verify that the chimney vent termination outside your home is not blocked by ice, bird nests, or debris. If the venting is clear and the tube is intact, the pressure switch diaphragm may be stuck or the draft inducer motor may not be spinning fast enough to close the switch.


Scenario 2: Burners Ignite for 2 to 5 Seconds and Then Immediately Shut Off



  • Root Cause: The furnace controller is failing to detect the flame. This is almost always caused by a dirty flame sensor rod. Over time, a thin layer of silica or carbon oxidation builds up on the metal rod, insulating it from the flame. This prevents the small microamp electrical current (flame rectification) from flowing through the flame to the ground, causing the control board to shut off the gas valve as a safety precaution.
  • Actionable Fix: Cut all electrical power to the furnace. Locate the flame sensor, which is a thin, bent metal rod mounted on a white ceramic insulator on the burner assembly opposite the igniter. Remove the single retaining screw holding it in place and slide the sensor out. Gently rub the metal rod with a piece of fine steel wool or a non-metallic abrasive pad to remove any invisible oxidation. Do not use sandpaper, as the silica residue left behind can permanently damage the sensor. Reinstall the clean sensor, restore power, and initiate the restart sequence.


Scenario 3: The Hot Surface Igniter Fails to Glow



  • Root Cause: The igniter has developed a hairline fracture or burned out. Silicon carbide igniters are highly fragile and subject to thermal stress from rapid temperature changes. Touching the black igniter element with bare fingers during installation leaves skin oils that create hot spots, causing premature failure.
  • Actionable Fix: Cut all power to the unit. Visually inspect the igniter element for any white spots, cracks, or breaks. To confirm it has failed, disconnect the igniter wiring harness and use a digital multimeter set to measure resistance (Ohms). Place the meter leads on the two pins of the igniter connector. A functional hot surface igniter should show a resistance reading between 40 and 90 Ohms. A reading of infinity (OL) indicates an open circuit, meaning the igniter is broken and must be replaced.


Scenario 4: The Furnace Is Completely Dead with No Lights or Blower Activity



  • Root Cause: There is an open safety limit switch or a complete loss of low-voltage control power. This is often caused by a tripped rollout switch (due to flame rollout from clogged burners), a tripped high-limit safety switch (due to a severely clogged air filter overheating the heat exchanger), or a blown low-voltage fuse on the integrated control board.
  • Actionable Fix: Turn off the power and check your main air filter. If it is caked with dust, replace it immediately, as restricted airflow trips the high-limit switch. Locate the manual-reset flame rollout switches mounted near the burner openings (they feature a small red button in the middle of two wire terminals). If the button is popped up, press it firmly down to reset it. Finally, look at the main control board inside the blower compartment. Check the automotive-style 3-amp or 5-amp fuse (usually purple or amber) plugged into the board. If the metal link inside the fuse is broken, replace it with an identical fuse.

Frequently Asked Questions



Why is my furnace blowing cold air after a reset?

If your furnace blows cold air after a reset, the system is likely in a safety lockout. The indoor blower fan will run continuously to cool down the heat exchanger if a high-limit switch trips, or to purge the system of combustion gases after a series of failed ignition attempts. Check for a dirty air filter, ensure all supply registers are open, and inspect the flame sensor to make sure the burners are actually lighting.



Is there a physical reset button on my furnace, and where is it located?

Most modern gas furnaces do not have a single button labeled "Reset." Instead, you reset them by cycling the main power switch or circuit breaker. However, some models have manual-reset limit switches and rollout switches located near the burners or blower housing. Additionally, the indoor blower motor itself may feature a small, rubber-covered red button on its rear casing that resets the motor if it overheats.



How many times can I safely attempt to reset my gas furnace?

Do not attempt to reset your furnace more than two or three times in a row if it fails to ignite. Modern control boards will enter a hard lockout state (often lasting up to three hours) after multiple failed ignition attempts to prevent unburned fuel gas from building up in your home. If the furnace does not stay lit after two attempts, there is an underlying mechanical or electrical issue that you must identify and fix.



What should I do if I smell gas near the furnace during a restart?

If you smell a strong gas odor, do not attempt to turn on any lights, use your phone, or operate the furnace, as any spark could ignite the gas. Immediately evacuate everyone from the house, leave the front door open, and call your gas utility provider or local fire department from a safe location outside. Do not return to the home until a licensed technician or emergency responder declares it safe.



Why does my furnace keep tripping the circuit breaker?

A furnace that repeatedly trips the circuit breaker indicates a serious electrical issue, such as a short circuit in the blower motor windings, a failing inducer motor, or a damaged wire rubbing against the metal cabinet. It can also be caused by a overloaded circuit if other heavy appliances are sharing the same breaker. Do not continue resetting the breaker, as this can damage the system or cause an electrical fire. Contact a licensed electrician or HVAC technician to inspect the system.

Professional Heating Solutions and Safety Inspections

If your furnace continues to lock out, makes unusual noises, or fails to ignite after following these steps, your system requires professional diagnosis. Do not attempt to bypass safety switches or hot-wire gas valves, as doing so poses severe risks of fire, carbon monoxide poisoning, or equipment damage.


How to Restart a Furnace After Running out of Oil (with Pictures)

How to Restart a Furnace After Running out of Oil (with Pictures)

Read also: FBI Agent Salary: How Much Do FBI Special Agents Really Make?
close