How To Reset Daikin Aircon: Step-by-Step Troubleshooting And System Restore Guide

How To Reset Daikin Aircon: Step-by-Step Troubleshooting And System Restore Guide

How To Reset A Daikin Air Conditioner | Storables

To reset a Daikin air conditioner, disconnect its power source by turning off the outdoor isolator switch and the main indoor circuit breaker for at least 5 to 10 minutes, allowing the system’s capacitors to discharge completely and clear the printed circuit board (PCB) memory. For minor system glitches, you can perform a soft reset by holding down the power button on the wireless remote control or pressing the manual ON/OFF switch on the indoor unit chassis. Executing this procedure clears temporary fault codes and recalibrates the electronic expansion valve (EEV) and thermistors for optimal operation.

Crucial Diagnostics and Safety Checks Before Resetting Your Daikin AC

Before initiating a system-wide reset on your Daikin split system, multi-split, or VRV (Variable Refrigerant Volume) unit, you must understand that a reset is a diagnostic tool, not a permanent cure for mechanical or electrical failures. Daikin air conditioners utilize advanced self-diagnostic onboard microcomputers that monitor system pressure, refrigerant temperatures, voltage fluctuations, and fan motor speeds.

When a parameter falls outside safe operating tolerances, the indoor unit's green LED (Light Emitting Diode) light will blink, and the system will enter a safety shutdown mode to protect critical components like the scroll compressor or the inverter PCB.

Performing a hard reset clears the volatile RAM of the microcomputer. If the underlying fault is structural—such as a refrigerant leak, an electrical short, or a failing thermistor—the system will run briefly post-reset before triggering the safety lock again. Therefore, always document any blinking patterns or retrieve the active error codes before wiping the unit's memory.



Mandatory Pre-Reset Checklist



  • Essential Diagnostic Equipment: Daikin wireless remote controller (e.g., ARC480 or ARC452 series) or wired wall controller (BRC series), high-quality smartphone camera to document LED blinking sequences, and non-contact voltage tester.
  • System Knowledge Requirements: Location of the dedicated outdoor isolator switch (typically mounted on the wall adjacent to the outdoor condenser unit) and the location of the main electrical distribution board containing the aircon’s circuit breaker.
  • Estimated Cost: $0 (This is a manual hardware and software configuration process).
  • Execution Time: 10 to 15 minutes (Includes the mandatory capacitor discharge period).

Step-by-Step Daikin Aircon Reset and Calibration Methods

Follow these operational steps in sequence. Begin with the non-invasive soft reset and progress to a hard power-cycle reset if the system remains locked or continues to display error indicators.



Step 1: Retrieve and Document Active Error Codes

Do not clear the system memory without finding out why the unit tripped. Wiping the fault code makes it significantly harder for an HVAC technician to diagnose intermittent issues.



  1. Point your Daikin wireless remote control at the indoor unit.
  2. Press and hold the Cancel button for approximately 5 seconds. The temperature display on the remote screen will change to a double zero (00) and emit a single short beep.
  3. Release the button, then press the Cancel button repeatedly, stepping through the alphanumeric error codes.
  4. Listen to the indoor unit's response. Most codes will emit a short single beep. When the remote displays the active system error code, the indoor unit will emit a continuous, long beep.
  5. Note this code (e.g., U4 for a communication error, E7 for an outdoor fan motor lock, or L5 for an inverter compressor overload) before proceeding.


Step 2: Perform a Soft Reset via the Remote and Chassis

If the indoor unit is unresponsive but has no major fault codes, a soft reset can re-establish communication between the handheld remote and the internal receiver PCB.



  1. Press the ON/OFF button on the remote control to turn the system off.
  2. Remove the slide-off battery cover on the back of the remote control. Remove both AAA batteries.
  3. Press and hold any button on the remote for 15 seconds to drain any residual capacitive charge in the remote's internal transmitter chip.
  4. Reinsert fresh, high-quality alkaline batteries, ensuring the polarities align with the markings inside the battery compartment.
  5. Walk to the indoor wall-mounted unit. Locate the manual ON/OFF button (frequently labeled as "Cool/Heat" or "Auxiliary") on the bottom right or behind the front grille panel.
  6. Press and hold this manual button for 5 seconds. The unit will beep twice, indicating it has completed a soft reset cycle and is ready to sync with the refreshed remote.


Step 3: Execute a Complete Hard Power-Cycle Reset

A hard reset is required if the system suffers from an electrical brownout lock, communication sync errors between the indoor and outdoor PCBs, or a persistent safety lockout state.



  1. Switch off the air conditioner using the remote control and wait 2 minutes for the louvers to close completely and the fan to stop spinning.
  2. Locate the outdoor unit. Positioned within arm's reach of the condenser, you will find a weatherproof, gray isolator switch box. Turn the switch handle from the ON position to the OFF position.
  3. Locate your home’s main electrical service panel. Find the circuit breaker labeled "AC," "Aircon," or "Daikin" and flip it to the OFF position.
  4. Keep the power completely disconnected for a minimum of 10 minutes.

Warning: Do not rush this waiting period. Daikin inverter-driven air conditioners contain heavy-duty electrolytic capacitors on the outdoor main control board that hold high-voltage electricity to run the variable-speed compressor. It takes up to 8 minutes for these capacitors to fully discharge. Re-energizing the unit too quickly will prevent the microprocessor from resetting its memory registers.



Step 4: Re-Energize and Initialize the System

Once the capacitors have discharged, you must restart the system in a specific order to ensure proper sensor calibration and valve positioning.



  1. Flip the indoor circuit breaker back to the ON position.
  2. Turn the outdoor isolator switch back to the ON position.
  3. Wait 3 to 5 minutes before turning the unit on with the remote. During this startup window, you may hear faint clicking and whirring sounds from the indoor and outdoor units. This is normal; the system is performing a self-test, resetting the Electronic Expansion Valve (EEV) to its starting position, and reading ambient thermistor values.
  4. Press the ON/OFF button on the remote control. Select Cooling Mode, set the temperature to 22°C (72°F), and set the fan speed to High.
  5. Monitor the indoor unit. The green operation lamp should illuminate steadily. Cold air should begin flowing within 3 minutes as the compressor ramps up speed.

Daikin Air Conditioner Fault Codes - Aircon Astiquer - Aircon Blinking ...

Daikin Air Conditioner Fault Codes - Aircon Astiquer - Aircon Blinking ...

Daikin System Error Codes, Meanings, and Reset Protocols

Use this diagnostic matrix to determine whether a standard hard reset will resolve your Daikin air conditioner's fault or if immediate professional physical intervention is required.



Error Code System Component Affected Primary Root Cause Reset Resolution Potential Recommended Action Protocol
A1 Indoor Unit PCB Microprocessor program crash or EEPROM corruption. Medium Try a 10-minute hard power reset. If the code returns, replace the indoor PCB.
A6 Indoor Fan Motor Fan motor overload, dust accumulation, or wiring failure. Low Check for physical obstructions in the fan wheel before attempting a hard reset.
C9 Indoor Thermistor Suction air thermistor resistance value out of spec. Low Typically requires a physical component replacement; resetting will only clear the code for a few minutes.
E7 Outdoor Fan Motor Fan motor locked, connector loose, or driver PCB fault. Low to Medium Check for wind blockages or debris in the outdoor unit. Power-cycle the isolator switch.
H9 Outdoor Thermistor Outdoor air thermistor failure or dirty condenser coil. Medium Clean the outdoor heat exchanger fins and perform a hard reset to clear the sensor reading.
L5 Inverter Compressor Instantaneous overcurrent or short circuit in the compressor. Very Low Severe electrical fault. Do not attempt multiple resets; call a certified technician immediately.
U4 Signal Transmission Communication failure between indoor and outdoor units. Medium Often caused by power surges. A full 10-minute hard reset of both units simultaneously often restores sync.
UA System Combination Incompatible indoor/outdoor units or incorrect local settings. Low Occurs after new installations or PCB swaps. Requires address setting adjustments, not just a reset.

Diagnosing Post-Reset Failures and Persistent System Faults

If your Daikin air conditioner fails to operate correctly after a complete hard reset, look at these three common failure scenarios to find the source of the issue.



Scenario 1: The Green Operation Light Starts Flashing Immediately Upon Power-Up



  • Root Cause: The indoor unit microprocessor is detecting an active hard fault during its initial self-test. This is usually caused by an open circuit in one of the copper pipe thermistors (liquid or gas line sensors) or a failed communication channel (U4 error) where the indoor unit is not receiving a signal feedback loop from the outdoor condenser's mainboard.
  • Actionable Fix: Check the wiring connection block inside the indoor unit's side wiring compartment. Ensure the wires on terminals 1, 2, and 3 match the outdoor terminal block exactly. If the wiring is correct, test the resistance of the thermistors using a multimeter set to the kilo-ohms scale. A faulty sensor must be replaced to clear the flashing light.


Scenario 2: The Aircon Starts and Blows Air, but Shuts Down and Flashes After 3 Minutes



  • Root Cause: The 3-minute delay is the programmed compressor startup window. If the system shuts down exactly when the compressor tries to engage, the microcomputer has detected either a locked compressor rotor, a failure in the outdoor inverter PCB power module (IPM), or extremely high pressure in the refrigerant lines (often due to a completely blocked outdoor condenser coil or a closed service valve).
  • Actionable Fix: Turn off the power and inspect the outdoor condenser coil. If it is caked with dust, grass clippings, or pet hair, wash it gently with a garden hose. Ensure both service valves on the outdoor unit brass ports are fully open. If the issue remains, an HVAC specialist must measure the compressor winding resistance and system pressures.


Scenario 3: The Unit is Completely Dead with No Lights or Sounds After Restoring Power



  • Root Cause: There is an interruption in the main power line, a blown thermal fuse on the indoor unit transformer, or a failed surge protection varistor on the main PCB. This often happens after major lightning storms or power grid surges.
  • Actionable Fix: Verify that your household circuit breaker has not tripped back to the middle "neutral" position. Switch it fully OFF and then back to ON. Use a non-contact voltage tester to confirm that power is reaching the indoor terminal connection block. If 230V mains power is present but the unit is dead, remove the indoor PCB cover and inspect the glass tube fuse (typically 3.15A or 5A). Replace the fuse if the internal wire filament is broken.

Frequently Asked Questions



How do I reset my Daikin air conditioner remote control?

To reset a Daikin remote controller, slide off the rear battery cover, remove the batteries, and hold down the power button for 15 seconds to drain the residual charge. Next, reinsert fresh batteries and press the tiny recessed "Reset" button (if present on your specific model) using a paperclip or safety pin to restore the remote to its factory default settings.



Why is my Daikin aircon light blinking green and not cooling?

A blinking green light indicates that the system's self-diagnostic programming has detected an operational fault and has entered safety lockout mode to prevent component damage. To find the exact cause, use the "Cancel" button on your remote control to scroll through the diagnostic codes until you hear a long, continuous beep.



Does resetting a Daikin aircon clear the error code history?

A standard hard power reset clears the current active fault loop, allowing the unit to attempt a restart. However, it does not erase the permanent EEPROM installation history log, which can still be retrieved by professional Daikin service technicians using advanced field diagnostic software.



Where is the physical reset button on a Daikin indoor unit?

Daikin indoor units do not feature a dedicated button labeled "Reset." Instead, the manual "ON/OFF" or "Cool/Heat" button located on the lower right corner of the chassis under the front intake panel serves as the physical hardware reset interface when held down for more than 5 seconds.



How long should I leave the breaker off to reset my Daikin AC?

You must leave the main circuit breaker and outdoor isolator switch turned off for a minimum of 10 minutes. This period is required to discharge the high-voltage inverter capacitors on the outdoor unit's power board, ensuring the volatile memory of the microprocessor is completely wiped.

Secure Professional Daikin Climate Control Assistance

If your Daikin system continues to lock out or display blinking error lights after a complete hard reset, the system requires professional diagnostics. Contact an authorized Daikin service partner today to inspect your inverter boards, thermistor arrays, and refrigerant levels to restore your home's comfort.


Daikin CTXG50EV1BW [178/393] Operation is not reset by malfunction code ...

Daikin CTXG50EV1BW [178/393] Operation is not reset by malfunction code ...

Read also: Pitt County Busted Newspaper: A Guide to Public Records, Local Arrest Trends, and Information Access